This research introduces an AI-driven framework for smart campus microgrids, designed to enhance environmental sustainability, disaster resilience, and student education in sustainable development. The framework features an enhanced multi-scale gated temporal attention network (MS-GTAN+) for end-to-end meteorological hazard-state recognition, achieving significant RMSE reductions (48.5% for wind speed, 46.0% for precipitation) with rapid inference (1.82 ms). Daily operations are optimized by a multi-intelligence co-optimization algorithm balancing economic efficiency and carbon reduction. During disasters, an improved PageRank algorithm dynamically prioritizes critical loads, boosting assurance rates to ~75% (nearly double traditional methods). An educational digital twin platform bridges theory and practice, demonstrating substantial improvements in carbon footprint reduction, power disruption resilience, and student competency. This holistic model supports universities in advancing sustainability and preparing future leaders.

Executive Impact: Key Metrics

Wind Speed RMSE Reduction
Critical Load Assurance Rate
Single-Sample Inference Time

Deep Analysis & Enterprise Applications

Select a topic to dive deeper, then explore the specific findings from the research, rebuilt as interactive, enterprise-focused modules.

AI-Driven Optimization
Disaster Resilience
Educational Empowerment
48.5%

RMSE Reduction (Wind Speed)

Our MS-GTAN+ model dramatically reduces prediction errors for wind speed and precipitation compared to traditional models, enabling more accurate and timely energy management decisions.

Integrated Prediction-Decision Pipeline

Raw Meteorological Data
GTCN Feature Extraction
Multi-Scale Feature Fusion
Adaptive Attention Pooling
Feature Refinement
Weather Class Classifier
Decision Output (Normal/Disaster)

The MS-GTAN+ integrates feature extraction, meteorological situational awareness, and scheduling strategy generation within a single deep neural network, ensuring real-time performance and accuracy.

MS-GTAN+ Performance vs. Baselines

Model Wind Speed RMSE Precipitation RMSE Inference Time (ms)
MS-GTAN+ 0.102 0.115 1.82
LSTM 0.105 0.118 1.95
Transformer 0.198 0.213 3.24
Informer2020 0.203 0.221 2.87

MS-GTAN+ demonstrates superior predictive accuracy and efficiency across all metrics, making it ideal for low-latency microgrid scheduling and hazard recognition.

75%

Critical Load Assurance Rate

Our improved PageRank algorithm ensures critical campus functions maintain power during disasters, nearly doubling the performance of traditional methods.

Dynamic Load Prioritization in a Blizzard Scenario

Problem: During a severe blizzard, the campus microgrid faced a 75% reduction in available power. Traditional static load prioritization methods failed to adequately protect essential services, leading to potential disruptions in core teaching and medical facilities.

Solution: The AI-driven framework, utilizing the improved PageRank algorithm, dynamically re-evaluated load criticality based on functional necessity, temporal sensitivity (increasing urgency with disaster duration), and power demand stability. This allowed for precise identification of 13 critical loads, including emergency lighting and medical equipment, enabling adaptive power redistribution.

Results: The dynamic prioritization achieved a critical load assurance rate of 83.19% and an average criticality score of 0.539, ensuring the continuity of essential services despite severe power constraints. This represented a substantial improvement over the traditional static method's 37.86% assurance rate.

Critical Load Guarantee Rate Improvement

Scenario Traditional Guarantee Rate Improved Guarantee Rate Response Time Difference
Typhoon 37.97% 75.62% -0.017 s
Heavy Rain 37.92% 75.40% -0.020 s
Snowstorm 37.86% 75.50% -0.008 s

Across all disaster scenarios, the improved PageRank algorithm significantly boosts the critical load guarantee rate, ensuring robust campus operation with minimal response time impact.

Bridging

Theory-Practice Gap

Our educational digital twin platform transforms theoretical AI concepts into practical, interactive learning experiences for students, enhancing sustainability decision-making competencies.

Interactive Learning for Microgrid Management

Problem: University students often struggle to connect theoretical knowledge of smart grids and AI with real-world energy management challenges, limiting their practical problem-solving skills in sustainability.

Solution: An educational digital twin platform was developed, allowing students to visualize real-time microgrid operations and AI-driven decision processes. Students can manipulate key algorithmic parameters (e.g., reward function coefficients, load priority weights) during simulated disaster scenarios (like typhoons) and immediately see the impact on critical load guarantee rates and energy curtailment levels.

Results: Simulation results demonstrated substantial improvements in student sustainability competency. Post-testing showed significant learning gains in smart grid and AI comprehension, while qualitative surveys indicated high student engagement and confidence in solving energy management problems. The platform fostered interdisciplinary adaptation and critical thinking.

Quantify Your AI Advantage

Estimate the potential annual savings and reclaimed operational hours for your organization by integrating AI-driven microgrid optimization.

Estimated Annual Savings $0
Reclaimed Operational Hours 0

Your Path to AI-Driven Sustainability

A structured approach to integrating this AI framework into your campus operations.

Phase 1: Discovery & Assessment

Collaborative workshops to define campus-specific energy goals, identify critical loads, and integrate existing data sources. Comprehensive assessment of current infrastructure and energy consumption patterns.

Phase 2: AI Model Customization & Training

Tailoring MS-GTAN+ and the improved PageRank algorithm to your campus microgrid architecture. Training AI models with historical meteorological and operational data for precise prediction and optimization.

Phase 3: Digital Twin Integration & Pilot Deployment

Deployment of the educational digital twin platform for student and faculty training. Pilot implementation of the AI framework in a designated microgrid zone with real-time monitoring and performance validation.

Phase 4: Full-Scale Rollout & Continuous Optimization

Expansion of the AI-driven framework across the entire campus microgrid. Establishing a continuous feedback loop for model refinement, performance monitoring, and adaptive strategy adjustments based on operational insights.