AI-assisted report generation offers significant opportunities to reduce radiologists' workload and improve diagnostic accuracy, especially for complex cases and workforce shortages. This paper introduces MAIRA-X, a clinically evaluated multimodal AI model for longitudinal chest X-ray (CXR) report generation, encompassing both clinical findings and lines and tubes (L&T) reporting. Developed using a large-scale, multi-site, longitudinal dataset of 3.1 million studies, MAIRA-X significantly improved AI-generated reports over the state of the art on lexical quality, clinical correctness, and L&T-related elements. A first-of-its-kind retrospective user evaluation study with nine radiologists found comparable rates of critical errors (3.0% for original vs. 4.6% for AI-generated reports) and a similar rate of acceptable sentences (97.8% for original vs. 97.4% for AI-generated reports). These results mark a significant improvement over prior user studies with larger gaps and higher error rates, suggesting MAIRA-X can effectively assist radiologists, particularly in high-volume clinical settings.

Executive Impact

MAIRA-X demonstrates a significant leap in AI-assisted radiology reporting, directly impacting clinical efficiency and patient safety.

0% Critical Error Rate (AI Reports)
0% Acceptable Sentences (AI Reports)
0% Reduction in AI Critical Errors (vs. prior studies)

Deep Analysis & Enterprise Applications

Select a topic to dive deeper, then explore the specific findings from the research, rebuilt as interactive, enterprise-focused modules.

Model Architecture
Clinical Evaluation
L&T Reporting

MAIRA-X integrates advanced vision and language models to achieve state-of-the-art CXR report generation. It leverages a large-scale dataset and multimodal inputs to generate accurate and contextually rich findings.

Enterprise Process Flow

CXR Images (Frontal, Lateral, Prior)
Contextual Data (Indication, Comparison, Prior Report)
RAD-DINO-X Vision Encoder & Vicuna-13B LLM
MAIRA-X Multimodal Report Generation
Draft Findings Report (Clinical Findings & L&Ts)

A rigorous user evaluation study with experienced radiologists assessed MAIRA-X's performance against human-written reports, focusing on critical errors, acceptable sentences, and overall clinical utility.

Radiologist User Study: Original vs. AI Reports
Metric Original Reports AI-Generated Reports
Critical Error Rate 3.0% (±0.8%) 4.6% (±1.0%)
Reports with at least one error 15.4% (±1.6%) 20.6% (±1.9%)
Acceptable Sentences 97.8% 97.4%
Reports with no changes needed 84.5% 79.4%
Notes: Error bars indicate 95% confidence intervals from 1,000 bootstrap resamples. Data derived from Table 2 and Figure 4 of the paper.

MAIRA-X introduces a novel L&T-specific metrics framework (RAD-LT-EVAL) and demonstrates significant improvements in accurately reporting lines and tubes, their changes, and placements.

Quantitative L&T Reporting Performance (Test Set)
Metric MAIRA-2 MAIRA-X
L&T-type/macro-F1 62.4 [61.2, 63.5] 81.1 [80.2, 81.9]
L&T-change/macro-F1 78.4 [76.8, 80.0] 87.5 [86.2, 88.7]
L&T-placement/macro-F1 70.5 [68.9, 72.1] 80.0 [78.8, 81.4]
L&T-counts/macro-accuracy 83.8 [83.5, 84.1] 88.9 [88.7, 89.1]
Notes: Values are mean and error bars are 95% confidence intervals (CI) for n = 500 bootstrapped samples. Data from Table 5.

Calculate Your Potential ROI

Estimate the potential return on investment for integrating MAIRA-X into your clinical workflow. MAIRA-X can reduce cognitive load and improve reporting efficiency for radiologists.

Annual Cost Savings $0
Hours Reclaimed Annually 0

Implementation Roadmap

Our structured implementation roadmap ensures a smooth and effective integration of MAIRA-X into your existing radiology systems.

Phase 1: Discovery & Customization

Initial assessment of current workflows, data integration planning, and customization of MAIRA-X to specific institutional guidelines. (~2-4 weeks)

Phase 2: Training & Pilot Deployment

Radiologist training on MAIRA-X interface and features, followed by a pilot deployment in a controlled clinical setting with ongoing feedback. (~4-8 weeks)

Phase 3: Full-Scale Integration & Optimization

Gradual rollout across relevant departments, continuous monitoring of performance, and iterative model optimization based on real-world usage and new data. (~8-16 weeks)

Ready to Transform Your Radiology Workflow?

Connect with our AI specialists to explore how MAIRA-X can enhance efficiency, accuracy, and reduce workload in your clinical practice.

Ready to Get Started?

Book Your Free Consultation.

Let's Discuss Your AI Strategy!

Lets Discuss Your Needs


AI Consultation Booking