Microwave imaging for human brain stroke detection using frequency domain inverse modelling & phantom experiments

This paper presents a novel approach to microwave imaging using Inverse Synthetic Aperture Radar (ISAR) for non-invasive brain stroke detection. It details a custom antenna design, the use of water as a matching medium, and a pseudo-inverse based back-projection algorithm for image reconstruction. Validation was performed in simulated environments and with biological surrogates (potatoes and turnips) containing artificial dielectric inclusions, demonstrating sub-centimeter resolution across a 26 cm circular imaging area. The findings suggest the technique's potential for detecting internal structural variations and lay the groundwork for future human brain imaging applications.

Executive Impact: Key Metrics

This research significantly advances non-invasive diagnostic capabilities for stroke, offering a portable and cost-effective alternative to traditional methods. The demonstrated sub-centimeter resolution in phantom experiments indicates a high potential for early and accurate detection, crucial for improving patient outcomes. The foundational work sets the stage for clinical applications, promising reduced diagnostic delays and enhanced accessibility.

0.0 cm Resolution Achieved (cm)
0 cm Imaging Area (cm)
<0s Diagnostic Speed (seconds)

Deep Analysis & Enterprise Applications

Select a topic to dive deeper, then explore the specific findings from the research, rebuilt as interactive, enterprise-focused modules.

Methodology

The research outlines a three-stage methodology: ideation, simulated environment image reconstruction, and real-environment image reconstruction. This systematic approach ensures thorough validation of the forward and inverse models before application to real biological objects. Key steps include antenna design, matching media integration, bistatic ISAR formulation, and pseudo-inverse based back-projection.

Antenna & Permittivity

A customized ultra-wideband (UWB) antenna with low ringdown characteristics and directional gain was developed to minimize self-generated clutter. Water was selected as a matching medium due to its specific permittivity-frequency relationship, mimicking biological tissues and ensuring effective electromagnetic coupling. CST simulations were used to optimize frequency sweep and propagation distance parameters.

Forward & Inverse Models

The forward model calculates scattering parameters based on antenna theory and object properties. The inverse model, utilizing a pseudo-inverse based back-projection algorithm (Moore-Penrose pseudo-inverse), reconstructs spatial scatterer maps. This approach allows for rapid anomaly localization under simplified assumptions of constant RCS, even with non-invertible sensitivity matrices.

Phantom Experiments

Practical validation involved organic biological surrogates like potatoes and turnips with artificial dielectric inclusions. These phantoms, while not anatomically equivalent to human tissue, allowed for initial assessment of resolution and anomaly detectability under realistic scattering conditions. Reconstructed images demonstrated the technique's capability to detect internal structural variations.

60 Seconds for Anomaly Localization

Enterprise Process Flow

Ideation
Simulated Environment Reconstruction
Real Environment Reconstruction

Comparison of Imaging Modalities for Stroke Detection

Microwave Imaging (MWI) offers distinct advantages over traditional Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) for stroke detection, particularly in emergency and bedside scenarios.

Feature Microwave Imaging (MWI) Computed Tomography (CT) Magnetic Resonance Imaging (MRI)
Cost
  • Low
  • High
  • Very High
Portability
  • High
  • Low
  • Low
Non-invasiveness
  • High (Non-ionizing)
  • Low (Ionizing Radiation)
  • High (Non-ionizing, but strong magnetic fields)
Accessibility
  • High (Bedside/Ambulance)
  • Limited (Specialized Facilities)
  • Limited (Specialized Facilities)
Tissue Contrast Mechanism
  • Dielectric Properties
  • X-ray Attenuation
  • Magnetic Field Response
Real-time Monitoring
  • Potential
  • Limited
  • Limited

Early Stroke Detection: A Critical Window

Early diagnosis and vigilant monitoring in the initial hours after a stroke are crucial for recovery and treatment outcomes. Ischemic strokes, the most common type, require thrombolytic drugs within a three-hour time-sensitive window from symptom onset. Current clinical modalities like CT and MRI are often limited by cost, lack of portability, and delayed accessibility, making timely intervention challenging. The portability and rapid anomaly localization (sub-60 seconds) offered by microwave imaging present a significant opportunity to bridge this gap, enabling faster diagnosis and potentially improving patient prognoses through quicker treatment.

Advanced ROI Calculator

Estimate the potential financial impact and efficiency gains AI could bring to your enterprise operations.

Estimated Annual Savings $0
Annual Hours Reclaimed 0

Phased Implementation Roadmap

A strategic roadmap for integrating AI, designed for minimal disruption and maximum impact.

Phase 1: Feasibility Assessment & Pilot (3-6 Months)

Conduct a detailed feasibility study and pilot project, focusing on specific stroke detection scenarios using phantoms. This involves validating the custom antenna, matching media, and the ISAR imaging algorithm in controlled laboratory settings, as presented in this research. Success metrics will include resolution, anomaly detectability, and processing speed.

Phase 2: Advanced Phantom Development & Optimization (6-12 Months)

Develop anatomically accurate, frequency-dispersive brain phantoms that mimic real tissue dielectric properties, including healthy and pathological brain matter. Refine the ISAR algorithm for improved contrast resolution and imaging fidelity, accounting for the complex electromagnetic interactions within the brain. Explore alternative coupling media and pulse rectification techniques.

Phase 3: Pre-Clinical Validation & System Refinement (12-18 Months)

Transition to pre-clinical validation using animal models or post-mortem human tissue, if ethically appropriate and approved. Focus on constructing sensitivity matrices based on real, heterogeneous objects to better model measurement uncertainty and noise. Compare pseudo-inverse solutions with other regularization techniques to enhance robustness and minimize inversion artifacts.

Phase 4: Clinical Trials & Regulatory Approval (18-36+ Months)

Initiate human clinical trials to evaluate the system's efficacy in detecting and differentiating stroke types in real-world patient settings. Work closely with regulatory bodies (e.g., FDA, MHRA) to secure necessary approvals for medical device use. This phase will involve extensive data collection, validation against existing gold standards (CT/MRI), and further system optimization based on clinical feedback.